What was found
STARTED APU ON LANDING ATTEMPTED TO BRING APU ELECTRICAL POWER ON BUSSES AND WOULD NOT HOLD AFTER 2ND BUSS ATTEMPTED ON TWO ATTEMPTS, ATTEMPTED TO PROVIDE APU BLEED AIR AT GATE ALSO AND THERE WAS ZERO APU BLEED DUCT PRESSURE. APU BITE PROCEDURE AMM TASK 49-60-801, FAULT 49-31171 INDICATED, PAGE 6 OF 16 49-60, TASK 801 LED TO TASK 49-31, TASK 808 PERFORMED FIM TASK 49-31-808A. -F 910 10 APU OPS NORMAL - ACCEPTS ALL BLEED AIR LOADS AND ELECTRICAL LOADS, INSPECTION OF TAIL PIPE PERFORMED.