What was found
AFT PIT NR 2 FLOOR PANEL IS CORRODED. REMOVED CORRODED MATERIAL LOSS, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53. FABRICATED FLOOR PANEL IAW SRM 51-40-05, TREATED NEW FLOOR PANEL IAW AMM 51-21-41-377-032, STEP D 1-6 AND PRIMED NEW FLOOR PANEL IAW SOPM 20 44 01, STEP D 1.C W 1.0 O .071 R 0 L 36 D .071.