What was found
FMC NR2, INOPERATIVE FFR SHOWED NUMEROUS OCCURRENCES OF FMC DATA FAIL. ACFT GROUNDED. PERFORMED FMCS SYS BITE PROCEDURE REF FIM 34-61, TASK 801. INFLIGHT FAULTS SHOWED FMC FAULTS ONLY ON FLIGHT, LEG 5. PERFORMED FMCS OPS TEST REF MM34-61-00. TEST PASSED. SENSOR TEST SHOWED NO CURRENT FAULTS, FMCS OK.