What was found
LEFT PACK LIGHT ON RECALL ON (UNREADABLE) EXTINGUISHES WITH MASTER CAUTION RESET. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROL BITE TEST, CLEARED FAULTS, OPS NORMAL REF MM 21-61-00-700-806-002. NO HISTORY LAST 60 DAYS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT PACK LIGHT ON RECALL ON (UNREADABLE) EXTINGUISHES WITH MASTER CAUTION RESET. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROL BITE TEST, CLEARED FAULTS, OPS NORMAL REF MM 21-61-00-700-806-002. NO HISTORY LAST 60 DAYS.