What was found
DURING APU START AT GATE, FAULT LIGHT ILLUMINATED. TURNED APU SWITCH OFF AND LIGHT WENT OUT. SECOND START WAS NORMAL. COMPLISHED APU BITE IAW FIM 49-60, TASK 801. CURRENT STATUS SHOWS NO FAULTS. FAULT HISTORY FOR PREVIOUS START SHOWS MX MESSAGE 49-41012, NO APU ROTATION SHUTDOWN. ACCOMPLISHED FIM 49-40, TASK 803 FAULT CLASSIFIED AS INTERMITTENT. APU GROUND START SUCCESSFUL.