What was found
LEFT PACK BLEED TRIP AT FL 400, RESET ONCE, BLEED TRIP HAPPENED AGAIN, RESET A SECOND TIME, LIGHT STAYED OUT. PERFORMED BLEED TRIP OFF LIGHT ON, FAULT ISOLATION IAW FIM TASK 36-10 TASK 801. PREFORMED PRELIMINARY CHECKS, FAULT ISOLATION PROCEDURES AND REPAIR CONFIRMATION TASK. NO DEFECTS NOTED.