What was found
AFT CARGO BAY, BS 727, CENTER FLOOR SUPPORT NUT PLATE RUSTED AND CORROSION ON SUPPORT. BLENDED CORROSION IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53. R & R CENTER FLOOR SUPPORT IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY, BS 727, CENTER FLOOR SUPPORT NUT PLATE RUSTED AND CORROSION ON SUPPORT. BLENDED CORROSION IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53. R & R CENTER FLOOR SUPPORT IAW SRM 51-40-02.