What was found
AFT CARGO BAY AT BS 947.5 ABOVE 27R FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION CHECK LIMITS FOUND TO BE OUT OF LIMITS, CUT OUT DAMAGE. FABRICATED NEW SECTION AND INSTALLED IAW SRM 53-60-53, FIG 101 51-10-02, 53-00-53.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY AT BS 947.5 ABOVE 27R FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION CHECK LIMITS FOUND TO BE OUT OF LIMITS, CUT OUT DAMAGE. FABRICATED NEW SECTION AND INSTALLED IAW SRM 53-60-53, FIG 101 51-10-02, 53-00-53.