What was found
AFT CARGO COMPT STA BS 827 S26R FLOOR SUPPORT CORRODED. BLENDED CORRODED CHECKED LIMITS FOUND TO BE OUT OF LIMITS CUT OUT DAMAGED FABRICATED NEW SECTION AND INSTALLED IAW SRM 53-60-53 FIG 101 51-10-02 , 53-00-53.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPT STA BS 827 S26R FLOOR SUPPORT CORRODED. BLENDED CORRODED CHECKED LIMITS FOUND TO BE OUT OF LIMITS CUT OUT DAMAGED FABRICATED NEW SECTION AND INSTALLED IAW SRM 53-60-53 FIG 101 51-10-02 , 53-00-53.