What was found
AFT CARGO BAY BETWEEN BS 907 AND 927, ABOVE S27L, FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION IAW SRM 51 10 02, FOUND TO BE OUT OF LIMITS IAW SRM 53 60 53. R & R FLOOR SUPPORT IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY BETWEEN BS 907 AND 927, ABOVE S27L, FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION IAW SRM 51 10 02, FOUND TO BE OUT OF LIMITS IAW SRM 53 60 53. R & R FLOOR SUPPORT IAW SRM 51-40-02.