What was found
RIGHT PACK AND MASTER CAUTION LIGHTS ILLUMINATED ON CLIMBOUT (APPROX 11,000). PERFORMED QRH PROCEDURE - SELECTED WARMER TEMP. PACK RESET OK. NO FAULTS LOGGED ON ZONE TEMP CONT, HOWEVER NOTICED RT RAM AIR DEFLECTOR DOOR REMAINS DEPLOYED DURING CYCLE/TEST. FOUND MODULATION PANELS & RAM AIR ACTUATOR OPERATE NORMAL. LUBRICATED DEFLECTOR DOOR PIANO HINGE & LINKAGE POINTS ON LT & RT SIDES. GROUND VERIFICATION PASS, ZONE TEMP BITE GOOD REF 21-61-00. SYS OPS NORMAL. REPLACED RT RAM-AIR ACTUATOR IAW AMM 21-51-21-000-801/-400-801 AS A PRECAUTIONARY MEASURE. OPS AND BITE CK GOOD. NO FURTHER DEFECTS NOTED.