What was found
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED UPON RECALL AFTER ENG START ON GROUND. ACFT GROUNDED. BITE TESTED BOTH ZONE TEMP CONTROLLERS IAW FIM 21-62, TASK 801. NR 1 CONTROLLER TEST GOOD. NR 2 CONTROLLER BIT AND PREV FLT FLT DECK TRIM VALVE LIGHT ILLUMINATED. LIGHT WENT ON ON VERIFY. NO HISTORY PAST 30 DAYS.