What was found
MAIN CABIN FLOOR RT SIDE BS 986, BL 45 WEB HAS LIGHT CORROSION AROUND FASTENER HOLES. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51-1A-1. ORIGINAL MATERIAL THICKNESS IS .1500, REMOVED .0030, .1470 MATERIAL REMAINING IS FOUND TO BE WITHIN LIMITS, APPLIED ALODINE AND PRIMER IAW SRM 51-20-01. APPLIED CORROSION BLENDOUT MARKING IDENTIFIER IAW AMM 51-05-01-701.