Service difficulty report · Circuit Breaker · Boeing 737990ER

Difficulty date
May 6, 2013
Submitted
May 8, 2013
Operation
Air carrier
Aircraft
N419AS
Make and model
Boeing 737990ER
Aircraft serial
41734
Aircraft time
313 hours, 90 cycles
Part
Circuit Breaker
Condition
Malfunctioned
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AT GATE, GROUND POWER FAILED TWICE, STARTED APU, AFTER PUSHBACK NOTICED BEEPING SOUND AND A ELECTRICAL LIGHT ILLUMINATED ON OVERHEAD PANEL. ACFT GROUNDED. PERFORMED FIM TASK AMM 24-34-802, FOUND SPCU INOPERATIVE LIGHT ON. RESET BOTH CIRCUIT BREAKERS SPCU NORMAL AND SPCU STBY. SUCCESSFULLY RESET. ALSO FIM TASK 24-31-801. FAULTS CLEARED. NO OTHER FAULTS NOTED. TESTED NORMAL.