What was found
FRAME AT BS 500B, LT SIDE FRAME AT BS 500B, LT SIDE HAS A CRACK AT THE FASTENER DIRECTLY ABOVE AND INBD OF THE 1 DIA WIRE PENETRATION HOLE APPROX .1250" LONG EXTENDING INBD BELOW STRINGER 20L, REPAIRED FRAME AT STA 500B IAW ASA EA 400 53, EA 10317.