What was found
RIGHT T/E CLOSE OUT PANEL CHAFED ON OTBD NR 6 FAIRING. ACFT GROUNDED. REMOVED, FABRICATED AND INSTALLED NEW CLOSEOUT PANEL IAW SRM 51-40-02 AND DWG 65-69646 AND MM 20-50-11-912-002.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT T/E CLOSE OUT PANEL CHAFED ON OTBD NR 6 FAIRING. ACFT GROUNDED. REMOVED, FABRICATED AND INSTALLED NEW CLOSEOUT PANEL IAW SRM 51-40-02 AND DWG 65-69646 AND MM 20-50-11-912-002.