What was found
APU BAY STIFFENER FOR AIR INTAKE AT APROX BS 1121 IS CORRODED. ACFT GROUNDED. REMOVED CORRODED AND CHECKED LIMITS, FOUND STIFFENER OUT OF LIMITS IAW SRM 53-80-13-1A-2. R & R STIFFENER IAW SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU BAY STIFFENER FOR AIR INTAKE AT APROX BS 1121 IS CORRODED. ACFT GROUNDED. REMOVED CORRODED AND CHECKED LIMITS, FOUND STIFFENER OUT OF LIMITS IAW SRM 53-80-13-1A-2. R & R STIFFENER IAW SRM 51-40-02-0G-0.