AFT GALLEY FLOOR SUPPORT WEB ANGLE RT BS 986 - 1006 IS CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 56-30-51, FIG 101. R & R SUPPORT ANGLE IAW SRM 51-40-02.