What was found
MLG WW LOWER AFT STRUCTURE HAS SEVERAL AREAS OF CORROSION AND BARE METAL. ACFT GROUNDED. REMOVED DAMAGED. FOUND TO BE OUT OF LIMITS. FABRICATED NEW STRUCTURE AND REPLACED IAW SRMS 53-60-71-1A-1, 51-40-02-0G-0 AND 51-40-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MLG WW LOWER AFT STRUCTURE HAS SEVERAL AREAS OF CORROSION AND BARE METAL. ACFT GROUNDED. REMOVED DAMAGED. FOUND TO BE OUT OF LIMITS. FABRICATED NEW STRUCTURE AND REPLACED IAW SRMS 53-60-71-1A-1, 51-40-02-0G-0 AND 51-40-05.