What was found
FORWARD GALLEY SERVICE DOOR BS 194.5 S9R EVIDENCE OF A CRACK FIN RADIUS OF FRAME SUPPORT. ACFT GROUNDED. R & R FRAME SUPPORT IAW SRM 51-40-05-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD GALLEY SERVICE DOOR BS 194.5 S9R EVIDENCE OF A CRACK FIN RADIUS OF FRAME SUPPORT. ACFT GROUNDED. R & R FRAME SUPPORT IAW SRM 51-40-05-0G-0.