What was found
NO SATCOM BUTTON AVAILABLE ON FMC WHEN MENU IS SELECTED. ACFT GROUNDED. PERFORMED FIM 23-15, TASK 801. FOUND IRIDIUM TRANSCEIVER IS LOCKED UP IAW FIM 23-15, TASK 801 (C4). PERFORMED MANUAL POWER CYCLE, CYCLED CIRCUIT BREAKER P18-2 D14. MCDU SATCOM PROMPT RETURNED. PERFORMED SAT COM OPS CHECKED IAW MM 23-15-00-730-801. OPS CHECKED NORMAL.