What was found
EXTERNAL POWER RECEPTACLE DOOR 114AR FWD MATING SURFACE BENT ACCOMPLISHED HFEC ON MATING SURFACE IAW NDT MANUAL 51-00-00, PAR 23, PT 6 NO CRACK INDICATIONS NOTED T8257B. PERFORMED DETAILED VISUAL INSP IAW REO G16840 NO DAMAGE NOTED. REFORMED MATING SURFACE IAW REO G16840. PERFORMED HFEC ON MATING SURFACE IAW NDT MANUAL 51-00-00, PROC 23, PT 6 IAW REO G16840. NO CRACK INDICATIONS NOTED AT THIS TIME T8257A. MADE SURFACE ROUGHNESS 63 MICRO INCHES RA IAW REO G16840. PRIMED SURFACE AS REQUIRED IAW AMM 51-21-72 AND ASA EA NUMBER 800-53EA-11497.