What was found
AFT CARGO DOOR SILL BEAM WEB ST 256R BETWEEN BS 787 AND BS 847, FWD FACE OF WEB CONTAINS DRILL DAMAGE ON ALL SECTIONS OF WEB. ACFT GROUNDED. BLENDED DAMAGED AREAS, FOUND TO BE OUT OF LIMITS, LOCATED AND DRILLED NEW SILL BEAM WEB IAW SRM 53-670-15-1A-1, 51-40-05-0G-0.