What was found
AUTOTHROTTLES CIRCUIT BREAKER TRIPPED OPEN, AUTOTHROTTLES INOPERATIVE. ACFT GROUNDED. DFCS FAULT CODE 22-31263, REPLACED FCC A IAW FIM 22-31, TASK 801, MM 22-11-33. DFCS BITE GROUP NR 35 LRU REPLACEMENT TEST FOR FCC A PASS, DFCS BITE GROUP NR 49 LAND VERIFY PASS. AUTOTHROTTLE OPS TEST NORMAL IAW MM 22-31-00, A/T BITE TESTS NORMAL IAW FIM 22-31 TASK 801. HGS SENSOR TEST FOR FCC/AT PASS IAW MMS 34-36-00. GROUND VERIFICATION SUCCESSFUL. LWMP STATUS REMAINS CAT IIIA AUTOLAND AND HGS.