What was found
RT T/E CLOSE OUT PANEL CHAFED OTBD NR 6 FLAP FAIRING. ACFT GROUNDED. FABRICATED NEW IAW SRM 51-40-05-0G-0, RESTORED FINISH IAW BSOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT T/E CLOSE OUT PANEL CHAFED OTBD NR 6 FLAP FAIRING. ACFT GROUNDED. FABRICATED NEW IAW SRM 51-40-05-0G-0, RESTORED FINISH IAW BSOPM 20-41-02.