What was found
FUNCTIONAL CHECK FOR PACK, HIGH FLOW INHIBIT FAILED WITH LT PACK OFF, CONFIGURATION WAS ALT 15,000 FT, PRESSURIZATION MODE SELECTOR MANUAL OUTFLOW VALVE ADJUSTED FOR ZERO CABIN RATE OF CLIMB RT PACK AUTO, LT PACK OFF, FLAPS UP. WHEN FLAPS SELECTED 1, CABIN DID NOT RATE UP. ACFT GROUNDED. PERFORM RESET PROCEDURE OF THE PACK/ZONE TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-62-TASK 801. OPS CHECKED GOOD. ON SUBSEQUENT CHECK FLIGHT, FUNCTIONAL CHECK FAILURE OF RT PACK FOR HIGH FLOW INHIBIT REPEATED. ON DEFERRAL.