AFT CARGO BAY SIDEWALL SUPPORT ATTACHED TO FRAME BS 887 CORRODED AROUND LOWER FASTENER HOLES. BLENDED AREAS FOUND TO BE OUT OF LIMITS, FABRICATED NEW SUPPORT AND INSTALLED IAW SRM 53-00-07-1A-1, 51-30-01-0G-0, 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY SIDEWALL SUPPORT ATTACHED TO FRAME BS 887 CORRODED AROUND LOWER FASTENER HOLES. BLENDED AREAS FOUND TO BE OUT OF LIMITS, FABRICATED NEW SUPPORT AND INSTALLED IAW SRM 53-00-07-1A-1, 51-30-01-0G-0, 51-40-02-0G-0.