What was found
APU RT TORQUE BOX AREA, APU INLET CUTOUT LWR STRINGER IS CORRODED, ACFT GROUNDED. BLENDED DAMAGED AREA REMAINING MATERIAL FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED STRINGER AND INSTALLED NEW STRINGER IAW SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU RT TORQUE BOX AREA, APU INLET CUTOUT LWR STRINGER IS CORRODED, ACFT GROUNDED. BLENDED DAMAGED AREA REMAINING MATERIAL FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED STRINGER AND INSTALLED NEW STRINGER IAW SRM 51-40-02-0G-0.