What was found
CRACK FOUND ON FUSELAGE SKIN STA 941 TO 944.2, BETWEEN STR 24R AND 25R. ACFT GROUNDED. REPAIRED SKIN IAW SRM 53-00-01-2R-31, CAT B REPAIR INSPECTION THRESHOLD 66,000, FOR METHOD AND INTERVAL REFER TO OPERATORS REPAIR ASSESSMENT PROGRAM.