What was found
AUTO FAIL AND ALT LIGHTS ILLUMINATED ON PRESSURIZATION CONTROL PANEL. SWITCH IN AUTO POSITION. ACFT GROUNDED. FOUND NR 2 CONTROLLER FAULT INDICATED. ACCOMPLISHED FIM TASK 21-31, TASK 827. FOUND CONTROL MODULE AND SYS WIRING FAULTS. CLEARED FAULTS REF SAME, NR 2 CABIN PRESSURE CONTROLLER, OPS NORMAL AND REPAIR CONFIRMED, REF MM 21-31, TASK 801.