What was found
LEFT LOWER FUSELAGE EXTERNAL FWD A/C BAY GROUND SERVICE ACCESS DOOR CUTOUT FAIRING INBD SIDE SKIN IS BENT. ACFT GROUNDED. REMOVED DAMAGE IAW SRM 53-00-01-1A-1. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01-1A-1. FABRICATED -1, DOUBLER, -4 FILLERS, -5 TAPERED SHIMS AND INSTALLED REPAIR PARTS IAW SRM 53-30-01-2R-2. THIS IS A CATEGORY B REPAIR WITH AN INTERVAL OF 4,500 CYCLES THRESHOLD OF 60,000 CYCLES. CURRENT CYCLES AT TIME OF REPAIR 42,511.