F/A REPORTS L1 DOOR VERY DIFFCUT TO LATCH CLOSED. ACFT GROUNDED. LUBED L1 DOOR, REF 12-25-21. PERFORMED FORWARD ENTRY DOOR TEST AMM REF 25-11-00. GVI PERFORMED AND DOOR FOUND SERVICEABLE. DOOR TORQUE TEST PERFORMED AND CHECK GOOD. AMM REF 25-11-00, DOOR GOOD FOR CONTINUED SERVICE. NO HISTORY LAST 90 DAYS