What was found
WING ANTI-ICE, RT VALVE OPEN LIGHT ILLUMINATED & REMAINED ILLUMINATED WITH WING ANTI-ICE SWITCH OFF. ACFT GROUNDED. PERFOROMED FIM TASK 30-11, TASK 803 UP TO STEP E (2) (D). R & R RT WING THERMAL ANTI-ICE SHUTOFF VALVE, IAW AMM 30-11-11-000-801 , 30-11-11-400-801, 30-11-00-710-801. BONDING CHECK GOOD IAW MM 30-11-11-400-801, PG2, ITEM G (2). OPS & LEAK CHECKED NORMAL WING ANTI-ICE RIGHT VALVE LIGHT NORMAL OPERATION.