Service difficulty report · Control Valve · Boeing 737890

Difficulty date
February 9, 2014
Submitted
February 11, 2014
Operation
Air carrier
Aircraft
N516AS
Make and model
Boeing 737890
Aircraft serial
39044
Aircraft time
19,761 hours, 6,131 cycles
Part
Control Valve
Part number
3989084
Part serial
11542
Condition
Malfunctioned
Location
Rt A/C Pack
Part time
17,577 hours, 5,573 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB OUT, RT PACK LIGHT ILLUMINATED. QRH PROCEDURE RAN. LIGHT REMAINED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROL BITE. FOUND RT PACK TCV FAULT. REPLACED RT PACK TCV REF: FIM TASK 21-62 TASK 831, MM 21-51-10. OPS CKD GOOD NO FAULTS, REF: MM 21-51-10. ACCOMPLISHED ALT DEACTIVATION PROCEDURES REF MPM CH5 TABLE 3 ITEM 1. REPLACED PRECAUTIONARILY THE NR 2 ACAU. ALL GROUND VERIFICATION TEST PASSED.