What was found
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL AND EXTINGUISHED ON RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ ZONE TEMP CONTROLLER BITE TEST. FLIGHT DECK TRIM VALVE LIGHT ILLUMINATED ON RT PACK / ZONE TEMP CONTROLLER. REPLACED CONTROL COMPT TRIM AIR MODULATING VALVE. OPS NORMAL, NO LEAKS NOTED.