As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELECTRIC LIGHT ILLUMINATED. ACFT GROUNDED. CHECKED AND FOUND STATIC INVERTER REMOTE CIRCUIT BREAKER OUT. VERIFIED NO DEFECTS NOTED. RESET CIRCUIT BREAKER IAW AMM 20-60-01-860-801. PERFORMED ELECTRIC LIGHT BITE PROCEDURE NO FAULTS NOTED, IAW FIM 24-31 TASK 801. PERFORMED STATIC INVERTER FAULT PROCEDURE NO FAULTS NOTED REF FIM 24-34-801, NO HISTORY IN 30 DAYS.