Service difficulty report · Controller · Boeing 737890

Difficulty date
March 24, 2014
Submitted
March 26, 2014
Operation
Air carrier
Aircraft
N584AS
Make and model
Boeing 737890
Aircraft serial
35682
Aircraft time
25,132 hours, 7,512 cycles
Part
Controller
Part number
32902061
Part serial
3915
Condition
Failed
Location
Cabin Temp
Part time
25,141 hours, 7,517 cycles
Stage of operation
TX
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

UNABLE TO COOL AFT CABIN SUFFICIENTLY WITH BOTH FWD CABIN, AFT CABIN TEMP SELECTORS IN FULL COLD POSITIONS. ON GROUND SUPPLY DUCT TEMP FWD AFT 28C IN FLT 20C ALL INDICATIONS NORMAL NO ASSOCIATED LIGHTS LT PACK, TEMP 6C, RT PACK TEMP 40C THROUGHOUT FLIGHT. ACFT R & R RT ACM IAW MM 21-51-04. NEW ACM WILL NOT RUN. R & R ACM AGAIN IAW MM 21-51-04 AND STILL WILL NOT RUN, SWAPED TEMP CONTROLLERS & RT PACK OPS NORMAL & LT PACK NOW HAS SAME ISSUE. PROBLEM FOLLOWED THE CONTROLLER, SWAPPED CONTROLLERS BACK. REMOVED AND INSTALLED NEW NR 2 ZONE TEMP CONTROLLER REF 21-61-20-000-801. PERFORMED INSTALL TEST IAW SAME SYS CKS NORMAL. NO FAULTS LOGGED.