What was found
NOTICED TOXIC ELECTRICAL BURNING ODOR ON CAPTAINS SIDE OF COCKPIT. ACFT GROUNDED. INSPECT P18 PANEL FOUND T BLOCK 214G WITH DAMAGED WIRE TERMINAL. REMOVED 3 EA WIRES AT TERMINAL 5. WIRE NR`S W276-038, W018-306-10, W018-890-14 REF WIRE DIAGRAM 24-52-21. R & R TERMINAL BLOCK T214G SWDM 24-52-21, PG 1, T-BLOCK LUG 5 IAW SWPM 20-30-11.