What was found
FLOOR SUPPORT CORRODED BS 988 - 1016, RBL 31. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51-1A-1 FIG 103 AND FOUND OUT OF LIMITS IAW SRM 53-70-51-1A-1 FIG 103 DETAIL C. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT CORRODED BS 988 - 1016, RBL 31. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51-1A-1 FIG 103 AND FOUND OUT OF LIMITS IAW SRM 53-70-51-1A-1 FIG 103 DETAIL C. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02.