What was found
ON RECALL, AFT CABIN ZONE TEMP LIGHT ILLUMINATED. RAN CHECKLIST, LIGHT STAYED ON. ACFT GROUNDED. PERFORMED FIM 21-61, TASK 801 T/S. ALL BITE CHECKS ON ZONE TEMP CONTROLLER AND PASSED. FOUND AFT CABIN TEMP SENSOR INLET SCREEN CLOGGED, CLEANED SCREEN. RAN PACKS IAW AMM TASK 21-00-00-800-803, CHECKS GOOD.