What was found
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION RECALL. LIGHT EXTINGUISHES ON RESET. ACFT GROUNDED. R & R TRIM AIR MODULE VALVE REPLACED IAW IAW 21-61-021-00MM. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION RECALL. LIGHT EXTINGUISHES ON RESET. ACFT GROUNDED. R & R TRIM AIR MODULE VALVE REPLACED IAW IAW 21-61-021-00MM. OPS CHECKED GOOD.