What was found
DURING RECALL, ZONE TEMP ILLUMINATED FOR CONTROL CABIN. EXTINGISHED AT MASTER CAUTION RESET. ACFT GROUNDED. REPLACED CONTROL CABIN TRIM AIR MODULATING VALVE IAW AMM 21-61-21-000-801/-400-801. OPS AND LEAK CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING RECALL, ZONE TEMP ILLUMINATED FOR CONTROL CABIN. EXTINGISHED AT MASTER CAUTION RESET. ACFT GROUNDED. REPLACED CONTROL CABIN TRIM AIR MODULATING VALVE IAW AMM 21-61-21-000-801/-400-801. OPS AND LEAK CHECKED GOOD.