What was found
AFT PIT, LT TRANSITION PANEL CORRODED AT FASTENER HOLES INCLUDING HOLES UNDER SIDEWALL PANELS. FS 272-849. ACFT GROUNDED. R & R AFT PIT LT TRANSITION PANEL IAW SRM 53-00-53-2R-5 AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, LT TRANSITION PANEL CORRODED AT FASTENER HOLES INCLUDING HOLES UNDER SIDEWALL PANELS. FS 272-849. ACFT GROUNDED. R & R AFT PIT LT TRANSITION PANEL IAW SRM 53-00-53-2R-5 AND SRM 51-40-02.