What was found
MOP SILL IN FRONT OF LT AFT ENTRY DOOR FROM BS 947.5 - 986.5 SEVERAL AREA CORRODED. ACFT GROUNDED. REMOVED CORROSION ON MOP SILL, FOUND OUT OF LIMITS, REMOVED DAMAGED MOP SILL AND INSTALLED NEW MOP SILL IAW SRMS 53-60-15-1A-1, 51-40-02-0G-0W.