What was found
FWD CARGO FLOOR TO AFT BULKHEAD SUPPORT ANGLE CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. R & R NEW SUPPORT ANGLE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO FLOOR TO AFT BULKHEAD SUPPORT ANGLE CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. R & R NEW SUPPORT ANGLE IAW SRM 51-40-02.