Service difficulty report · Sensor · Boeing 737890

Difficulty date
June 15, 2014
Submitted
June 17, 2014
Operation
Air carrier
Aircraft
N532AS
Make and model
Boeing 737890
Aircraft serial
36346
Aircraft time
15,691 hours, 4,733 cycles
Part
Sensor
Part number
412A160041
Condition
Dirty
Location
Cockpit Temp
Stage of operation
TX
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CAB ZONE LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-61, TASK 801, SHOWED FLIGHT DECK TRIM VALVE FAULT ON NR 2 ZTC BUT VERIFY TEST PASSED WITH NO FAULTS. FOUND FLIGHT DECK TEMP SENSOR AND FILTER DIRTY. CLEANED SENSOR AND CLEANED FILTER IAW MM 21-61-06-100-801. PERFORMED CABIN TEMPERATURE CONTROL AND INDICATION. OPS TEST IAW MM 21-61-00-700-807-002 AND PACK/ ZONE TEMP CONTROLLER BITE IAW FIM 21-62 TASK 801. ALL TESTS PASS.