What was found
ELECTRIC LIGHT ILLUMINATED ON OVERHEAD ELECTRICAL PANEL. ACFT GROUNDED. PERFORMED BITE FOUND FAULT AUX BATTERY CHARGER INOPERATIVE IAW FIM 24-31, TASK 801. CLEARED FAULT, CONFIRMED THAT NO MESSAGE AND TWO GREEN LIGHTS ON FRONT OF THE AUX BATTERY CHARGER IN THE E&E BAY AND THAT WAS INTERMITTENT FAULT AND NO LONGER EXIST, CHECKED ELECTRICAL SYS, NORMAL IAW FIM 24-31, TASK 825.