What was found
NR 2 ENGINE TREND DATA SHOWS LOW PRESSURE ROTOR VIBRATION LEVELS STILL TRENDING HIGH BUT WITHIN LIMITS AFTER FAN BALANCE. DATA SCATTER INDICATES HARWARE INSPECTION AND FAN LUBE REQUIRED. ETOPS SIGNIFICANT SYSTEM TASK CARD 78472002. ACFT GROUNDED. ACCOMPLISHED FAN LUBE IAW W/C 78472002, FOUND 2 PLATFORMS W/ LOOSE & MISSING RUBBER MATERIAL NR 12 & 21. REMOVED LOOSE MATERIAL IAW MM 72-21-02-200-801-F00. CHANGED OUT SHIMS & REPLACED 24 EA ELASTIMER AXIAL PIN STOPS, IAW T/C 78472002.