As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT ZONE TEMP LIGHT CAME ON DURING RECALL, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. COULD NOT DUPLICATE. ACCOMPLISH FIM 21-62/816, WITH NO DEFECTS NOTED. ALSO RANG OUT S1077 AFT CABIN OVERHEAT SW, RANG OUT NORMAL BUT DID FIND PIN 1 BENT. REPLACED S1077 REF WDM:21-61-14 & MM:21-61-05 REPLACED PRECAUTIONARY RT PACK TEMP CONTROLLER REF MMM:21-61-20. ALL GROUND VERIFICATION OPS CK NORMAL.