What was found
FUEL PUDDLE UNDER NR 2 ENGINE. ACFT GROUNDED. PERFORMED NR 2 ENGINE VENT AND DRAIN INSPECTION IAW AMM 71-70-00-200-801-F00. FOUND RT VSV ACTUATOR LEAKING AT 9 DROPS A MINUTE. REPLACE RT VSV ACTUATOR WITHIN 75 CYCLES. ON DEFERRAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUEL PUDDLE UNDER NR 2 ENGINE. ACFT GROUNDED. PERFORMED NR 2 ENGINE VENT AND DRAIN INSPECTION IAW AMM 71-70-00-200-801-F00. FOUND RT VSV ACTUATOR LEAKING AT 9 DROPS A MINUTE. REPLACE RT VSV ACTUATOR WITHIN 75 CYCLES. ON DEFERRAL.